AED 7000

AED 7000

FEATURES:

  • THREE-STEP DEFIBRILLATION
  • TWO BUTTON OPERATION
  • VOICE AND VISUAL PROMTS FOR OPERATOR
  • BIHASIC ENERGY OUTPUT
  • AUTOMATIC SELF-TEST DAILY BATTERY CONDITION TEST
  • LOCK-OUT PROTECTION

DETAILED SPECIFICATIONS:

DEFIBRILLATOR  
OUTPUT BIPHASIC TRUNCATED EXPONTIAL
ENERGY SEQUENCE 150J, 150J, 200J
CHARGE TIME 8 SECONDS TO 150J
ANALYSIS TIME 9 SECONDS
MAXIMUM TIME FROM INITIATION OF RHYTHM ANALYSIS TO READINESS FOR DISCHARGE WITH A NEW BATTERY LESS THAN 20 SECONDS
MAXIMUM TIME FROM INITIATION OF RHYTHM ANAYLSIS TO READLINESS FOR DISCHARGE AFTER 6 SHOCKS LESS THAN 25 SECONDS

 

MAXIMUM TIME FROM INITIALLY SWITCHING POWER TO READLINESS FOR DISCHARGE

 

LESS THAN 30 SECONDS
AUDIBLE PROMPTS 22 AUDIBLE PROMPTS
VISUAL PROMPTS LED PROMPTS, AUTOMATIC SELF-TEST
CONTROLS TWO BUTTONS – ON/OFF, SHOCK
OUTPUT ENERGY ACCURACY +/- 15% INTO ANY IMPEDANCE FROM 25 TO 175 OHMS
THE MAXIMUM VOLTAGE 1200 +/- 50V
OUTPUT DISABLED WHEN THE PATIENT IMPEDANCE IS OUTSIDE LIMITS 20 TO 200 OHMS
BATTERY
PART NO. CR123A-4X2
NON-RECHARGEABLE 2.8Ah
CAPACITY 100 DISCHARGES AT 200J OR 120 DISCHARGES AT 150J
DIMENSIONS 303MM X 216MM X 8MM
WEIGHT 2.0KG

More Information

FEATURES:

  • THREE-STEP DEFIBRILLATION
  • TWO BUTTON OPERATION
  • VOICE AND VISUAL PROMTS FOR OPERATOR
  • BIHASIC ENERGY OUTPUT
  • AUTOMATIC SELF-TEST DAILY BATTERY CONDITION TEST
  • LOCK-OUT PROTECTION

DETAILED SPECIFICATIONS:

DEFIBRILLATOR  
OUTPUT BIPHASIC TRUNCATED EXPONTIAL
ENERGY SEQUENCE 150J, 150J, 200J
CHARGE TIME 8 SECONDS TO 150J
ANALYSIS TIME 9 SECONDS
MAXIMUM TIME FROM INITIATION OF RHYTHM ANALYSIS TO READINESS FOR DISCHARGE WITH A NEW BATTERY LESS THAN 20 SECONDS
MAXIMUM TIME FROM INITIATION OF RHYTHM ANAYLSIS TO READLINESS FOR DISCHARGE AFTER 6 SHOCKS LESS THAN 25 SECONDS

 

MAXIMUM TIME FROM INITIALLY SWITCHING POWER TO READLINESS FOR DISCHARGE

 

LESS THAN 30 SECONDS
AUDIBLE PROMPTS 22 AUDIBLE PROMPTS
VISUAL PROMPTS LED PROMPTS, AUTOMATIC SELF-TEST
CONTROLS TWO BUTTONS – ON/OFF, SHOCK
OUTPUT ENERGY ACCURACY +/- 15% INTO ANY IMPEDANCE FROM 25 TO 175 OHMS
THE MAXIMUM VOLTAGE 1200 +/- 50V
OUTPUT DISABLED WHEN THE PATIENT IMPEDANCE IS OUTSIDE LIMITS 20 TO 200 OHMS
BATTERY
PART NO. CR123A-4X2
NON-RECHARGEABLE 2.8Ah
CAPACITY 100 DISCHARGES AT 200J OR 120 DISCHARGES AT 150J
DIMENSIONS 303MM X 216MM X 8MM
WEIGHT 2.0KG